  • SMG2000E Double Clamps Digital Phase Meter

    SMG2000E Double Clamps Digital Phase Meter is a high-precision, hand-held, two-channel instrument designed to measure voltage, current and phase measurement on site.

    Product Details of SMG2000E Double Clamps Digital Phase Meter


    Product Introduction

    The Double Clamps Digital Phase Meter is a portable, high-precision instrument for on-site voltage, current, and phase measurements. It enables safe, non-intrusive testing (no need to disconnect lines) and can measure phase differences (U-U, I-I, U-I), phase sequence, transformer wiring groups, differential protection systems, and meter connections. With fully insulated dual-channel inputs, it prevents short circuits and equipment damage. The high-contrast LCD (up to 25mm characters) features a 70° adjustable viewing angle for optimal readability. Ideal for field diagnostics with reliability and ease of use.


    Ürün Özellikleri

    1、Compact & Handheld Design – Portable and user-friendly.

    2、Wide Measurement Range – Measures current (10mA–10A) and voltage (3V–500V) without breaking the circuit.

    3、High-Contrast LCD – 25mm-tall characters with 70° adjustable tilt for optimal visibility.

    4、Intuitive Function Switch – Quickly toggle between voltage, current, and phase measurements.

    5、High-Precision Clamp Sensors – 0.1mA current & 0.1V resolution (patented technology).

    6、Low Power Consumption – Energy-efficient design with battery voltage monitoring.


    Ürün parametreleri

    Reference to working conditions

    Çevre sıcaklığı(23±5)℃
    Ortam nemi(45~75)% RH
    Measured signal waveformSine wave、β=0.02
    Measured signal frequency(50±0.2)Hz
    The position of the measured current-

    carrying conductor at the clamp mouth

    any
    The amplitude of The measured signal when

    measuring The phase

    100~220V、0.5~1.5A
    External reference frequency electromagnetic

    field interference

    Should be avoided

    Measurement error of AC voltage

    Limit of quantityÇözünürlükBasic error limit
    20V0,01V±(0.3% reading +0.2% range)
    200V0.1V
    500V1V


    Measurement error of ac current

    Limit of quantityÇözünürlükBasic error limit
    200mA0.1mA±(0.3% reading +0.2% range)
    2A1mA
    10 A10mA

    Voltage input circuit impedance when u1-u2 phase is measured:40KΩ

    MenzilÇözünürlükBasic error limit
    0~360°±2°

    Rated working condition

    Çevre sıcaklığı(0~40)℃
    Ortam nemi(20~80)% RH
    Measured signal waveformSine wave、β=0.05
    Measured signal frequency(50±0.5)Hz
    The position of the measured current-

    carrying conductor at the clamp mouth

    any
    The amplitude of The measured signal when

    measuring The phase

    U1-U2 phase: 30V ~ 500V
    I1-I2 phase: 10mA ~ 10.00A
    U1-I2 phase or I1-U2 phase: 10V ~ 500V, 10mA ~ 10.00A
    External reference frequency electromagnetic

    field interference

    Should be avoided
    Limit of rated operating errorUnder the above rated working conditions, the rated working error limit of each measured shall not exceed twice the corresponding basic error limit

    Other technical features

    Display digitThree and a half
    Örnekleme oranı3 times per second
    Güç kaynağıSingle 9V laminated battery, The power supply current is less than 5mA
    Genel boyutlarıCase size192×95×55mm3
    Clamp shell size140×42×20mm3
    Çene boyutuΦ7mm×9mm
    AğırlıkBody280g
    Test forceps2×200g
    Depolama koşullarıSıcaklık-10℃~50℃







    Bunları da beğenebilirsin

    • Herhangi Bir Sorunuz Var mı?

      HER ZAMAN BİZİMLE İLETİŞİME GEÇMEKTEN ÇEKİNMEYİN
      Bize Ulaşın
    • Bizi ziyaret et

      Bina 6, Optik Vadisi Optik-Mekanik Endüstri Parkı, 84 Gaoxin 5 Yolu,
      East Lake Yeni Teknoloji Geliştirme Bölgesi, Wuhan Şehri, Hubei Eyaleti, Çin

    • Bize e-posta gönderin

      qiao@hvtest.cc

    • Bizi Arayın

      +86-15871365102