qiao@hvtest.cc15871365102

    < >

    GM-5kV Adjustable Insulation Resistance Tester Meter

    GM-5kV Insulation Resistance Tester The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment.

    Product Details of GM-5kV Adjustable Insulation Resistance Tester Meter


    Insulation Resistance Tester

    1. Technique specifications

    Output voltage level

    0.1kV0.25kV0.5kV1kV2.5kV5kV

    Test voltage accuracy

    ±(5%10V)

    Short-circuit current

    Typical value 10mA

     

    2.Range and accuracy

    Range

    Effective range of resistance measurement

    Accuracy

    20MΩ

    0.0119.99MΩ

    ±(5%+3d)

    200MΩ

    5.0199.9MΩ

    ±(5%+3d)

    2000MΩ

    501999MΩ

    ±(5%+3d)

    20GΩ

    0.519.99GΩ

    ±(5%+3d)

    200GΩ

    5.0199.9GΩ

    ±(10%+3d)

    2000GΩ

    501999GΩ

    ±(20%+10d)

     

     

    3.Basic parameters

    Anti electric field interference ability

    2mA(50/60Hz)

     

    Time and alarm functions

     

    The stopwatch shows a maximum of 19 minutes and 59 seconds. Cycle every 20 minutes. The sounding point is 15 seconds, 60 seconds, every minute

    A short beep is sounded at the point, the resistance reading is held for 3 seconds, the measured resistance is lower than the lower limit of the range, and a continuous audible alarm is given when the reading is invalid

    Display table

    3pcs 0f Three and a half LCD digital meter heads, respectively, display test voltage, resistance, time

    Power supply

    Built-in rechargeable lithium battery, DC15V power supply. With AC (50 / 60Hz) special adapter access port to charge the battery

    Use environment

    Temperature: -20℃ ~+ 40; relative humidity: 20%90%

    Diemension

    315×240×180mmLength×Width×Height

    Weight

    5.5kg

     

    Nickname: Insulation Resistance Tester; Insulation Meter

    Features

    1. Strong anti-interference ability: the anti-interference ability of electric field induction reaches 2mA (50Hz), and it is known that the insulation resistance parameters of 500000 V large-scale transformer can be measured at the site of 500000 V substation without disconnection

     

    2. Large short-circuit current: the typical value of short-circuit current is 10mA, which is suitable for the test of large capacity and large inductance

     

    3. Wide resistance measurement range: the measurement range is from 0.01MΩto 1999gΩ, with accurate reading and high resolution

     

    4. Wide high voltage output range: 0.1kv, 0.25kv, 0.5kV, 1kV, 2.5KV, 5kV can be selected, and the voltage can be adjusted smoothly from 0V to the required voltage

     

    5. Acousto-optic reminder: it has the function of timing, reminding the user to record and analyze the absorption ratio and polarization index of the measured object

     

    6. All key parts are imported components to ensure the accuracy of measurement

     

    7. Easy to use: integrated case, small size, light weight, easy to carry

     

    8. Beautiful appearance: solid and abrasive materials are used to make the overall texture and service life of the instrument longer