  • YDQW Series Inflatable No Partial Discharge Test Transformer

    SF6 gas with high insulation strength as insulation medium. Small local discharge capacity, rated voltage local discharge capacity ≤ 5PC. High level craftsmanship, beautiful appearance, and easy handling

    Product Details of YDQW Series Inflatable No Partial Discharge Test Transformer

    Product Introduction:

    Used for manufacturers of electrical appliances, cables, motors, transformers, mutual inductors, insulation materials, and related high-voltage components, as well as high-voltage testing laboratories in power, scientific research, and universities, to conduct partial discharge and power frequency withstand voltage tests on their products.


    Technical parameters:

    Parametreler

    Value

    Değerlendirilmiş kapasite

    50-1200kVA

    Giriş gerilimi

    380V

    Çıkış voltajı

    50-1200kV

    Koşu süresi

    ≤5 dakika

    Ölçüm doğruluğu

    ≤1.5%

    Partial discharge capacity

    ≤5Pc

    Protection function

    Overcurrent and voltage protection alarm automatically return to zero


    Özellik:

    1. Filled with SF6 gas, which features high insulation strength, as the insulating medium.

    2. Compact and lightweight design with high-quality craftsmanship, attractive appearance, and easy handling.

    3. Benefiting from the arc-extinguishing properties and specialized structural design involving SF6 gas, the unit exhibits low partial discharge levels, measuring ≤5 PC at rated voltage.

    4. The testing process is simple, intuitive, and user-friendly.

    5. Effectively eliminates clutter interference from the power supply.

    6. Integrates automatic control technology, offering a high degree of automation and strong anti-interference capability.

    7. Equipped with a fast-acting electronic protection device, ensuring high reliability.


    Working principle:

    The control panel (box) with overcurrent automatic tripping and zero position interlocking device to prevent sudden pressurization of the power input is regulated by an autotransformer to input voltage into a non partial discharge filter isolation filter transformer, and then output from the non partial discharge filter isolation filter transformer

    To test the primary winding of the transformer, according to the principle of electromagnetic induction, the secondary (high voltage) winding can obtain an equal multiple of voltage amplitude - power frequency high voltage - based on the ratio of its turns to the primary winding.








    Bunları da beğenebilirsin

    • Herhangi Bir Sorunuz Var mı?

      HER ZAMAN BİZİMLE İLETİŞİME GEÇMEKTEN ÇEKİNMEYİN
      Bize Ulaşın
    • Bizi ziyaret et

      Bina 6, Optik Vadisi Optik-Mekanik Endüstri Parkı, 84 Gaoxin 5 Yolu,
      East Lake Yeni Teknoloji Geliştirme Bölgesi, Wuhan Şehri, Hubei Eyaleti, Çin

    • Bize e-posta gönderin

      qiao@hvtest.cc

    • Bizi Arayın

      +86-15871365102